- Wide Measurement Range & High Precision: Measures turbidity from 0 to 1000 NTU with 0.1 NTU precision, ensuring reliable water quality monitoring for wastewater treatment, environmental monitoring, and water purification.
- Advanced Scattering Light Technology: Utilizing 90° scattering light, it provides stable and accurate turbidity readings even in challenging conditions.
- Robust and Durable Design: With an IP68 rating, it is built to withstand harsh environments, ideal for long-term use in water treatment and environmental applications.
- Seamless Integration and Easy Calibration: Supports RS-485 Modbus-RTU communication for easy integration with industrial systems, featuring automatic temperature compensation and simple calibration for consistent performance.
- Versatile and User-Friendly: Designed for a variety of water quality applications, this sensor ensures easy installation and maintenance in both industrial and environmental settings.
- Easy Integration and Versatile Application: This sensor can be seamlessly integrated with the SenseCAP S2100 LoRaWAN datalogger and
SenseCAP Sensor Hub 4G Data Logger for efficient data collection and management.
Monitor key indicators of water quality with our advanced IP68 RS485 turbidity sensor designed for applications such as industrial wastewater treatment, environmental monitoring and water purification. The sensor provides accurate turbidity measurements to ensure reliable performance for water quality management in industrial and natural water systems. It can be used in a variety of RS 485 systems to provide the accuracy required for efficient monitoring and management.
We offer the SenseCAP S2100 - LoRaWAN® Data Logger and SenseCAP Sensor Hub 4G Data Logger suitable for RS485 sensors, you can transmit the sensor data to public LoRaWAN® network servers(Helium, TTN, etc.,) or MQTT private servers.
Model | S-DTS210-01 |
Power | 12 ~ 24 V/DC (Typical 12 V/DC) 0.3W @ 12V |
Measurement Principle | Scattering light |
Measurement Range | 0~1000.0NTU |
Resolution | 0.1NTU/0.1℃ |
Accuracy | ±5% F.S, ±0.3°C |
Calibration Method | Two-point calibration |
Temperature Compensation | Automatic temperature compensation (Pt1000) |
IP Ratings | IP68 |
Operating Temperature | 0 ~ 50°C, < 0.2 MPa |
Storage Temperature | -5 ~ 65°C |
Installation | Mmersion installation, 3/4" NPT thread |
Cable Length | 10 meters |
Dimension | 185*Φ30mm |
unit:mm
- Water Treatment: Used in wastewater treatment plants to monitor water quality and ensure that effluent meets regulatory standards before discharge.
- Environmental Monitoring: Ideal for monitoring water bodies such as rivers, lakes, and reservoirs, providing real-time data on turbidity levels to assess water quality and pollution.
- Industrial Applications: Integrated into industrial processes to measure the turbidity of water used in manufacturing, ensuring clean and safe water for operations.
- Aquaculture: Used to monitor water quality in fish farming, where turbidity levels can affect the health of aquatic life.
- Hydrological Studies: Used in scientific research for studying sediment levels and water clarity in different environmental conditions, such as wetlands and watersheds.
Industrial Turbidity Sensor User Manual
HSCODE | 9031809090 |
USHSCODE | 9026104000 |
UPC | |
EUHSCODE | 9013101000 |
COO | CHINA |
Shipping rates Australia wide and New Zealand
FAQ:
- How do I estimate shipping for my order?
- Add products in the shopping cart and head to the checkout page to estimate the shipping.
Dispatch time
Unless expressly agreed otherwise with you, we will not commence delivery of an order until we have received cleared payment of the purchase price in full.
All orders placed before 11 am AEST (Monday to Friday) will ordinarily be processed on the same day.
We will endeavour to ship the Products by the applicable time indicated on the website, but all times are indicative only. All shipping times are dispatch times only, and actual delivery dates will depend on the shipping method chosen, delivery address and delivery service provider.
Note- Please make a note during purchase if you require any item urgently. However we cannot guarantee that we will be able to comply with any request.
*Go to Australia post delivery time calculation to get various Australia post service in your area please use our shipping postcode Thomastown, 3074 as the "from" address - https://auspost.com.au/parcels-mail/delivery-times.html?ilink=tools-open-deliv-times.
We ship all products throughout mainland Australia, Tasmania and New Zealand - Including Darwin, Melbourne, Sydney, Tasmania, Adelaide, Brisbane, Perth, all metro and regional areas but do not deliver to areas in Australia where the Australia Post delivery network is not available.
Check Express shipping delivery coverage area at - http://auspost.com.au/parcels-mail/delivery-areas.html
Receipt of deliveries
Deliveries to post office boxes are not permitted where delivery is by courier. If delivery is by courier and nobody is available at the delivery address to accept delivery when delivery is attempted then the courier may either:
- leave the relevant parcel at the unattended address (the courier will do so if specified in your delivery requirements); or
- re-attempt delivery at a later time or date, in which case we may charge you an additional re-delivery fee.
Note that if a delivery is left unattended at the shipping address and is subsequently stolen then the theft is your responsibility, not ours.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.